Download
Dry Type Transformer Catalogue
|
|
|
- Standard Dry Type Ventilated Transformers are
cooled by natural circulation of the surrounding air through its
windings. For trouble free operation and long life expectancy,
the ventilating air must be reasonable free from dust, moisture
or other damaging corrosive fumes. For this reason, standard Dry
Type ventilated transformers are normally installed in suitable,
indoor locations where they are protected from damaging elements.
- Some specifications require installation of
transformers in hazardous surroundings where the above condition
can be met.
- Epoxy Potted Transformers (also referred to
as Epoxy Resin Encapsulated) are designed for such conditions.
- Typical areas of use include: Corrosive environments
- Petro-Chemical, steel, pulp and paper industries; Damp conditions
- Mines, pump-houses, underground or rooftop service areas; Airborne
dust, conductive particles
Features
- Mixture of silica sand resin forming a solid
mass completely encloses and protects the core and coil, also
significantly reduces audible noise.
- Windings utilize Class 220oC Insulating
rated for 150oC Rise, but designed to operate at 115oC
maximum.
- The transformer's core is solidly grounded.
- Enclosure constructed from heavy gauge steel,
coated with ASA#61 grey powder paint
- Suitable for NEMA/CSA Type 3R and Type 4 Enclosure
applications for both indoor and outdoor
- Spacious wiring compartment, cool and easily
accessible (bottom or front access may depend on size)
- Standard Primary Taps
- CSA Certified, File No. LR34493
- UL Listed, File No. E108255
- ISO9001 Quality Certification
Common Part Numbers
& Typical Information
|
Typical Sizes
|
1-Phase 600-120/240
|
1-Phase
480-120/240 |
Approximate Weight
|
Enclosure Size No.
|
Enclosure Size No.
|
Dimensions WxDxH (inch)
|
0.25 KVA |
SC0.250JK/EP
|
SC0.250HK/EP
|
17LBS
|
1E
|
1E
|
5x4.25x9.75
|
0.50 KVA |
SC0.500JK/EP
|
SC0.500HK/EP
|
20LBS
|
1E
|
2E
|
5.87x4.87x10.25
|
0.75 KVA |
SC0.750JK/EP
|
SC0.750HK/EP
|
23LBS
|
1E
|
3E
|
7.5x6.12x11
|
|
1KVA
|
SC1JK/EP
|
SC1HK/EP
|
27LBS
|
2E
|
4E
|
9.75x12x16.25
|
|
1.5KVA
|
SC1.5JK/EP
|
SC1.5HK/EP
|
40LBS
|
3E
|
5E
|
15.5x14x19.25
|
|
2KVA
|
SC2JK/EP
|
SC2HK/EP
|
45LBS
|
3E
|
6E
|
15.5x15x25.5
|
|
3KVA
|
SC3JK/EP
|
SC3HK/EP
|
55LBS
|
3E
|
7E
|
15x15x15
|
|
5KVA
|
SC5JK/EP
|
SC5HK/EP
|
170LBS
|
4E
|
8E
|
21x18x17.5
|
7.5 KVA |
SC7JK/EP
|
SC7HK/EP
|
180LBS
|
4E
|
9E
|
21x22x20
|
|
10KVA
|
SC10JK/EP
|
SC10HK/EP
|
235LBS
|
5E
|
10E
|
32x22x25
|
|
15KVA
|
SC15JK/EP
|
SC15HK/EP
|
296LBS
|
5E
|
|
|
|
25KVA
|
SC25JK/EP
|
SC25HK/EP
|
355LBS
|
6E
|
|
|
|
37.5 KVA
|
SC37JK/EP
|
SC37HK/EP
|
395LBS
|
6E
|
|
|
|
|
|
|
|
|
|
|
Typical Sizes
|
3-Phase 600-208Y/120
|
3-Phase 480-208Y/120
|
Approximate Weight
|
Enclosure Size No.
|
|
|
|
3KVA
|
BC3JM/EP
|
BC3HM/EP
|
|
|
|
|
|
6KVA
|
BC6JM/EP
|
BC6HM/EP
|
130LBS
|
7E
|
|
|
|
9KVA
|
BC9JM/EP
|
BC9HM/EP
|
200LBS
|
7E
|
|
|
|
15KVA
|
BC15JM/EP
|
BC15HM/EP
|
415LBS
|
8E
|
|
|
|
30KVA
|
BC30JM/EP
|
BC30HM/EP
|
536LBS
|
9E
|
|
|
|
45KVA
|
BC45JM/EP
|
BC45HM/EP
|
645LBS
|
9E
|
|
|
|
75KVA
|
BC75JM/EP
|
BC75HM/EP
|
1300LBS
|
10E
|
|
|
Available Options
Include:
- Temperature Rise (80oC)
- Other Primary or Secondary Voltages
- Different frequency (other than 60Hz)
- Stainless Steel Enclosure & Hardware
- Electrostatic Shield (single, double, triple
or multiple/ultra)
- Custom sizes (specific KVA ratings)
- K-Factor Rated (K4, K9, K13, K20, K30)
- Special Paint/Finish
* Information is subject
to change without prior notice. |
|